4 Ways Ltd - Industrial and Scientific Vacuum Specialists 4 Ways Ltd 4 Ways Ltd 4 Ways Ltd 4 Ways Ltd

 

 

Auckland Chamber of Commerce

Masport Performance and Horse Power Requirements

PUMP SPECIFICATIONS

MASPORT PUMP  MODEL H5F H5V H75F H75V H75WF H75WV H15WF H15WV HXL5F HXL5V HXL75F HXL75V HXL75WF/V HXL15WF/V HXL20WF/V
Cooling Method Air Air Liquid Liquid Air Air Liquid Liquid Liquid
Recommended Optimum Tank Capcity - gallons 1000 -2,200 1800 - 3800 2000 - 5500 3000 - 6000 1000 - 2400 1800 - 4000 2000 - 5700 3000 - 6000 + TBA
Displacement CFM @ RPM 120 @ 1100 180 @ 1100 209 @ 1275 314 @ 1275 152 @ 1400 204 @ 1250 229 @ 1400 332 @ 1350 TBA
RPM range 1000 - 1100 1000 - 1100 1000 - 1275 1000 - 1275 1000 - 1450 1000 - 1300 1000 - 1450 1000 - 1400 TBA
Maximum Continuous Vacuum - "Hg 20 20 27 27 20 20 27 27 TBA
Maximum Intermitent Vacuum - "Hg 27 27 27 27 27 27 27 27 TBA
Maximum Continuous Pressure - PSIG 20 20 30 30 20 20 30 30 TBA
Maximum Intermitent Pressure - PSIG 25 25 35 35 25 25 35 35 TBA
Port Size - BSP tba 2 1/2" 2 1/2" 3" tba 2 1/2" 2 1/2" 3" 3"
Lubrication System Type P/V Actuated P/V Actuated P/V Actuated P/V Actuated Mech Oil Pump Mech Oil Pump Mech Oil Pump Mech Oil Pump Mech Oil Pump
Adjustable Oil Flow Rate Yes Yes Yes Yes Yes Yes Yes Yes Yes
Lubrication Points 3 3 3 4 3 3 3 4 4
Remote Lubricator Oil Capacity - Gallons 1.6 1.6 1.6 1.6 - - - - -
HXL Lubricator Oil Capacity - Gallons - - - - 1.2 1.2 1.2 1.2 -
Remote Oil Reservoir Capacity - Gallons 1 1 1 1 1 1 1 1 1
Net Weight - Kgs 62 72 75 86 75 98 123 136 75 86 89 100 98 111 138 149    
 

PERFORMANCE DATA - VACUUM

MASPORT PUMP  MODEL RPM CFM CFM and ACFM @ VACUUM - "Hg Max Vacuum Hg" Horsepower Req'd @ Hg"
    5 10 15 18 20 22 24 25 26 27 Continuous Intermittent 15 20 27
H5F, H5V 1100 120 CFM 92 71 50 37 28 21 15 10 7 2 20 27 4.9 5.4 5.9
ACFM 110 106 100 92 84 78 75 60 52 20
H75F, H75V 1100 180 CFM 126 99 70 54 43 31 20 14 7.5 3 20 27 7.6 8.5 9.6
ACFM 151 149 140 135 129 116 100 84 56 30
H75WF, H75WV 1275 209 CFM 145 114 82 63 49 37 23 16 9.2 3.1 27 27 8.6 9.2 9.8
ACFM 174 171 164 158 147 139 115 96 69 31
H15WF, H15WV 1275 314 CFM 205 160 116 87 69 52 32 22 13 5 27 27 13 14.3 16
ACFM 246 240 232 218 207 195 160 132 98 50
HXL5F, HXL5V 1400 152 CFM 112 89 64 50 40 31 20 15 11.7 8.2 20 27 6.2 6.8 7.5
ACFM 134 133 128 125 120 116 100 90 88 82
HXL75F, HXL75V 1250 204 CFM 152 113 80 62 49 37 24 19 14.5 9 20 27 8.6 9.6 10.9
ACFM 182 169 160 155 147 138 120 114 108 90
HXL75WF, HXL75WV 1400 229 CFM 172 134 96 72 59 45 31 24 17 10 27 27 9.5 10.1 10.8
ACFM 206 201 192 180 177 168 155 144 127 100
HXL15WF, HXL15WV 1350 322 CFM 247 190 139 107 87 66 47 37 26 16.6 27 27 13.8 15.1 16.9
ACFM 296 285 278 267 261 247 235 222 195 166
HXL20WF, HXL20WV     CFM                              
ACFM                              
 

PERFORMANCE DATA - PRESSURE

MASPORT PUMP  MODEL RPM CFM SCFM @ PSIG Max Vacuum Hg" Horsepower Req'd @ PSIG
  5 10 15 20 25 30 35 Continuous Intermittent 5 10 15 20 25 30 35
H5F, H5V 1100 120 104 98 92 86 77 - - 20 27 4.9 6.9 8.7 10.7 12.4 - -
H75F, H75V 1100 180 145 138 128 117 113 - - 8.6 11.1 13.8 16.3 19.2 - -
H75WF, H75WV 1275 209 170 161 153 146 130 115 96 30 27 9.8 12.8 18.6 2 22 26 28
H15WF, H15WV 1275 314 243 225 207 188 170 152 133 14 18 23 27.5 32 36 40
HXL5F, HXL5V 1400 152 131 127 121 115 108 - - 20 27 6.2 8.8 11 13.6 15.7 - -
HXL75F, HXL75V 1250 204 170 164 156 147 137 - - 9.8 12.6 15.7 18.5 21.8 - -
HXL75WF, HXL75WV 1400 229 193 183 172 162 151 140 130 30 27 10.8 14 20.4 21.9 24.2 28.5 30.8
HXL15WF, HXL15WV 1350 322 278 265 253 238 223 210 197 14.8 19.1 24.4 29.1 33.9 38.1 42.4
HXL20WF, HXL20WV                                    

Download the above chart in Microsoft Excel format

Previous Page

Index

Top